Adaptive Filtering and Characteristics Extraction for Impedance Cardiography

Adaptive Filtering and Characteristics Extraction for Impedance Cardiography

Year:    2014

Journal of Fiber Bioengineering and Informatics, Vol. 7 (2014), Iss. 1 : pp. 81–90

Abstract

Impedance Cardiography (ICG) is a noninvasive technique for monitoring stroke volume, cardiac output and other hemodynamic parameters, which is based on sensing the change of thoracic electrical impedance caused by blood volume change in aorta during the cardiac cycle. Motion artifact and respiratory artifact can lead to baseline drift in ICG signal, particularly during or after exercise, which can cause errors when calculating hemodynamic parameters. This paper presents an LMS-based adaptive filtering algorithm to suppress the respiratory artifact of ICG signal without restricting patients' breath. Estimation of hemodynamic parameters requires error-free automatic extraction of the characteristic points. Wavelet transform is used for extracting characteristic points which include its peak point (Z), start point (B) and end point (X) of left ventricular ejection time.

You do not have full access to this article.

Already a Subscriber? Sign in as an individual or via your institution

Journal Article Details

Publisher Name:    Global Science Press

Language:    English

DOI:    https://doi.org/10.3993/jfbi03201407

Journal of Fiber Bioengineering and Informatics, Vol. 7 (2014), Iss. 1 : pp. 81–90

Published online:    2014-01

AMS Subject Headings:   

Copyright:    COPYRIGHT: © Global Science Press

Pages:    10

Keywords:    Impedance Cardiography

  1. Automatic analysis of pre‐ejection period during sleep using impedance cardiogram

    Forouzanfar, Mohamad | Baker, Fiona C. | Colrain, Ian M. | Goldstone, Aimée | de Zambotti, Massimiliano

    Psychophysiology, Vol. 56 (2019), Iss. 7

    https://doi.org/10.1111/psyp.13355 [Citations: 25]
  2. A Real‐Time Heart Rate Detection Algorithm Based on Peripheral Electrical Bioimpedance

    Mansouri, Sofiene | Chabchoub, Souhir | Alharbi, Yousef | Alshrouf, Anwar | Nebhen, Jamel

    IEEJ Transactions on Electrical and Electronic Engineering, Vol. 17 (2022), Iss. 7 P.1054

    https://doi.org/10.1002/tee.23595 [Citations: 5]
  3. Detection of opening and closing of the aortic valve using impedance cardiography and its validation by echocardiography

    Bagal, Uttam R | Pandey, Prem C | Naidu, S M M | Hardas, S P

    Biomedical Physics & Engineering Express, Vol. 4 (2017), Iss. 1 P.015012

    https://doi.org/10.1088/2057-1976/aa8bf5 [Citations: 8]
  4. An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis

    Ali Sheikh, Shafa-at | Shah, Amit | Levantsevych, Oleksiy | Soudan, Majd | Alkhalaf, Jamil | Bahrami Rad, Ali | Inan, Omer T | Clifford, Gari D

    Physiological Measurement, Vol. 41 (2020), Iss. 7 P.075002

    https://doi.org/10.1088/1361-6579/ab9b71 [Citations: 7]
  5. Bioimpedance in Biomedical Applications and Research

    Wavelet Analysis in Impedance Rheocardiography

    Stepanov, Rodion | Dumler, Andrey | Podtaev, Sergey | Frick, Peter

    2018

    https://doi.org/10.1007/978-3-319-74388-2_13 [Citations: 2]
  6. Impedance cardiography signal denoising using discrete wavelet transform

    Chabchoub, Souhir | Mansouri, Sofienne | Salah, Ridha Ben

    Australasian Physical & Engineering Sciences in Medicine, Vol. 39 (2016), Iss. 3 P.655

    https://doi.org/10.1007/s13246-016-0460-z [Citations: 22]
  7. A Robust System for Longitudinal Knee Joint Edema and Blood Flow Assessment Based on Vector Bioimpedance Measurements

    Hersek, Sinan | Toreyin, Hakan | Inan, Omer T.

    IEEE Transactions on Biomedical Circuits and Systems, Vol. 10 (2016), Iss. 3 P.545

    https://doi.org/10.1109/TBCAS.2015.2487300 [Citations: 37]
  8. Real-time monitoring hypoxia at high altitudes using electrical bioimpedance technique: an animal experiment

    Yang, Lin | Dai, Meng | Cao, Qinglin | Ding, Shuai | Zhao, Zhanqi | Cao, Xinsheng | Wen, Zhihong | Wang, Hang | Xie, Manjiang | Fu, Feng

    Journal of Applied Physiology, Vol. 130 (2021), Iss. 4 P.952

    https://doi.org/10.1152/japplphysiol.00712.2020 [Citations: 2]
  9. Motion robust ICG measurements using a two-step spectrum denoising method

    Xie, Yao | Song, Rencheng | Yang, Dong | Yu, Honglong | Sun, Cuimin | Xie, Qilian | Xu, Ronald X

    Physiological Measurement, Vol. 42 (2021), Iss. 9 P.095004

    https://doi.org/10.1088/1361-6579/ac2131 [Citations: 6]
  10. Signal processing techniques applied to impedance cardiography ICG signals – a review

    Chabchoub, Souhir | Mansouri, Sofienne | Ben Salah, Ridha

    Journal of Medical Engineering & Technology, Vol. 46 (2022), Iss. 3 P.243

    https://doi.org/10.1080/03091902.2022.2026508 [Citations: 12]
  11. A Novel SVD Noise Cancellation Algorithm for ICG Signal

    Hadjer, Benabdallah | Salim, Kerai

    2021 IEEE 6th International Conference on Computing, Communication and Automation (ICCCA), (2021), P.157

    https://doi.org/10.1109/ICCCA52192.2021.9666326 [Citations: 0]
  12. A method for suppressing respiratory noise in impedance cardiography and comprehensive assessment of noise reduction performance

    Hung, Phan Dang | Dan, Chu Quang | Hai, Vu Duy

    Journal of Medical Engineering & Technology, Vol. 46 (2022), Iss. 2 P.116

    https://doi.org/10.1080/03091902.2021.2007304 [Citations: 3]
  13. Emerging Research in Computing, Information, Communication and Applications

    Removal of Baseline Wander from Physiological Signals Using Wavelet Transform

    Panse, M. S. |

    2016

    https://doi.org/10.1007/978-981-10-0287-8_20 [Citations: 0]