Year: 2014
Journal of Fiber Bioengineering and Informatics, Vol. 7 (2014), Iss. 1 : pp. 81–90
Abstract
Impedance Cardiography (ICG) is a noninvasive technique for monitoring stroke volume, cardiac output and other hemodynamic parameters, which is based on sensing the change of thoracic electrical impedance caused by blood volume change in aorta during the cardiac cycle. Motion artifact and respiratory artifact can lead to baseline drift in ICG signal, particularly during or after exercise, which can cause errors when calculating hemodynamic parameters. This paper presents an LMS-based adaptive filtering algorithm to suppress the respiratory artifact of ICG signal without restricting patients' breath. Estimation of hemodynamic parameters requires error-free automatic extraction of the characteristic points. Wavelet transform is used for extracting characteristic points which include its peak point (Z), start point (B) and end point (X) of left ventricular ejection time.
You do not have full access to this article.
Already a Subscriber? Sign in as an individual or via your institution
Journal Article Details
Publisher Name: Global Science Press
Language: English
DOI: https://doi.org/10.3993/jfbi03201407
Journal of Fiber Bioengineering and Informatics, Vol. 7 (2014), Iss. 1 : pp. 81–90
Published online: 2014-01
AMS Subject Headings:
Copyright: COPYRIGHT: © Global Science Press
Pages: 10
Keywords: Impedance Cardiography
-
Automatic analysis of pre‐ejection period during sleep using impedance cardiogram
Forouzanfar, Mohamad | Baker, Fiona C. | Colrain, Ian M. | Goldstone, Aimée | de Zambotti, MassimilianoPsychophysiology, Vol. 56 (2019), Iss. 7
https://doi.org/10.1111/psyp.13355 [Citations: 25] -
A Real‐Time Heart Rate Detection Algorithm Based on Peripheral Electrical Bioimpedance
Mansouri, Sofiene | Chabchoub, Souhir | Alharbi, Yousef | Alshrouf, Anwar | Nebhen, JamelIEEJ Transactions on Electrical and Electronic Engineering, Vol. 17 (2022), Iss. 7 P.1054
https://doi.org/10.1002/tee.23595 [Citations: 5] -
Detection of opening and closing of the aortic valve using impedance cardiography and its validation by echocardiography
Bagal, Uttam R | Pandey, Prem C | Naidu, S M M | Hardas, S PBiomedical Physics & Engineering Express, Vol. 4 (2017), Iss. 1 P.015012
https://doi.org/10.1088/2057-1976/aa8bf5 [Citations: 8] -
An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis
Ali Sheikh, Shafa-at | Shah, Amit | Levantsevych, Oleksiy | Soudan, Majd | Alkhalaf, Jamil | Bahrami Rad, Ali | Inan, Omer T | Clifford, Gari DPhysiological Measurement, Vol. 41 (2020), Iss. 7 P.075002
https://doi.org/10.1088/1361-6579/ab9b71 [Citations: 7] -
Bioimpedance in Biomedical Applications and Research
Wavelet Analysis in Impedance Rheocardiography
Stepanov, Rodion | Dumler, Andrey | Podtaev, Sergey | Frick, Peter2018
https://doi.org/10.1007/978-3-319-74388-2_13 [Citations: 2] -
Impedance cardiography signal denoising using discrete wavelet transform
Chabchoub, Souhir | Mansouri, Sofienne | Salah, Ridha BenAustralasian Physical & Engineering Sciences in Medicine, Vol. 39 (2016), Iss. 3 P.655
https://doi.org/10.1007/s13246-016-0460-z [Citations: 22] -
A Robust System for Longitudinal Knee Joint Edema and Blood Flow Assessment Based on Vector Bioimpedance Measurements
Hersek, Sinan | Toreyin, Hakan | Inan, Omer T.IEEE Transactions on Biomedical Circuits and Systems, Vol. 10 (2016), Iss. 3 P.545
https://doi.org/10.1109/TBCAS.2015.2487300 [Citations: 37] -
Real-time monitoring hypoxia at high altitudes using electrical bioimpedance technique: an animal experiment
Yang, Lin | Dai, Meng | Cao, Qinglin | Ding, Shuai | Zhao, Zhanqi | Cao, Xinsheng | Wen, Zhihong | Wang, Hang | Xie, Manjiang | Fu, FengJournal of Applied Physiology, Vol. 130 (2021), Iss. 4 P.952
https://doi.org/10.1152/japplphysiol.00712.2020 [Citations: 2] -
Motion robust ICG measurements using a two-step spectrum denoising method
Xie, Yao | Song, Rencheng | Yang, Dong | Yu, Honglong | Sun, Cuimin | Xie, Qilian | Xu, Ronald XPhysiological Measurement, Vol. 42 (2021), Iss. 9 P.095004
https://doi.org/10.1088/1361-6579/ac2131 [Citations: 6] -
Signal processing techniques applied to impedance cardiography ICG signals – a review
Chabchoub, Souhir | Mansouri, Sofienne | Ben Salah, RidhaJournal of Medical Engineering & Technology, Vol. 46 (2022), Iss. 3 P.243
https://doi.org/10.1080/03091902.2022.2026508 [Citations: 12] -
A Novel SVD Noise Cancellation Algorithm for ICG Signal
Hadjer, Benabdallah | Salim, Kerai2021 IEEE 6th International Conference on Computing, Communication and Automation (ICCCA), (2021), P.157
https://doi.org/10.1109/ICCCA52192.2021.9666326 [Citations: 0] -
A method for suppressing respiratory noise in impedance cardiography and comprehensive assessment of noise reduction performance
Hung, Phan Dang | Dan, Chu Quang | Hai, Vu DuyJournal of Medical Engineering & Technology, Vol. 46 (2022), Iss. 2 P.116
https://doi.org/10.1080/03091902.2021.2007304 [Citations: 3] -
Emerging Research in Computing, Information, Communication and Applications
Removal of Baseline Wander from Physiological Signals Using Wavelet Transform
Panse, M. S. |2016
https://doi.org/10.1007/978-981-10-0287-8_20 [Citations: 0]